PJ702C-LCD
Compact amplifier 700W.
COD.: PJ702C-LCD
Potencia: 700W
Features
PRIMARY APPLICATION: uncompromised amplification power at a very attractive price. Ideal for small to medium power stations.
AMPLIFIER FEATURES: high-gain amplifier with very low input drive power requirement and adjustable power output from 10 to 100 %.
HARDWARE FEATURES: extremely compact and rugged thanks to the stainless steel chassis, in only 2HE.
USER-FRIENDLY FEATURES: four pushbuttons for user/device interaction and software that offers a simple, intuitive interface.
OPERATING EFFICIENCY: incorporate a PFC (Power Factor Corrector) power supply, that provides the utmost efficiency for enhanced energy saving and environmental protection, which added to LD-MOSFET technology ensure high efficiency, better than 70% across the bandwidth.
EASE OF MAINTENANCE: advanced module engineering ensures extreme ease of access and simple maintenance. Includes an high performance air filter. The power supply is plug-in type, easily removable.
RELIABILITY/CONTINUITY: APC (Automatic Power Control) and Foldback protection ensure reliable operation under any operating conditions.
INTERFACE CONTROL: total control thanks to microprocessor easily programmed from menu with all key parameters displayed on LCD.
REMOTE CONTROL: electromechanically controllable and integrable into all digital ALTEL SISTEMAS telemetry systems.
REGULATORY COMPLIANCE: state-of-the-art technology in full compliance with EC, FCC and CCIR standards.
PJ702C-LCD | ||||
Parameters | Conditions | U.M. | Value | Notes |
GENERALS | ||||
Frequency range | MHz | 87,5 ÷ 108 | ||
Rated output power | W | 700 | ||
Spurious & harmonic suppression | dBc | <75 (80 typical) | Meets or exceeds all FCC and CCIR rules | |
Working temperature | °C | -5 to +50 | ||
Working humidity | % | 95 | No condensing | |
Working altitude | mt | Up to 3000 * | * With adequate air evacuation system in site | |
POWER REQUIREMENTS | ||||
Power supply type | Monophase | |||
AC Power input | AC Supply Voltage | VAC | 230 ±15% | Monophase |
AC Apparent Power Consumption | VA | 1002 | ||
Active Power Consumption | W | 1000 | ||
Overall Efficiency | % | Typical 70 | ||
Power factor | 0,998 | |||
Connector | VDE IEC Standard | |||
DC Power input | DC Supply Voltage | VDC | ||
DC Current | ADC | |||
MECHANICAL | ||||
Phisical dimensions | Front panel width | mm / inch | 483 / 19 | EIA rack |
Front panel height | mm | 88 | ||
Overall depth | mm | 390 | ||
Chassis depth | mm | 370 | ||
Weight | kg | About 10 | ||
Cooling type | Forced, with internal fan | |||
Power dissipated in heat | W | 300 | ||
Acoustic noise | dBA | < 75 | Leq 3 min @ 1 m | |
RF INPUT | ||||
RF Input | Connector | N type | ||
Impedance | Ohm | 50 | ||
Driver power for rated output | W | 15 | ||
Max input power before protection | W | 20 | ||
RF OUTPUTS | ||||
RF Output | Connector | N female type | ||
Impedance | Ohm | 50 | ||
RF Monitor | Connector | BNC | ||
Impedance | Ohm | 50 | ||
Output Level | dBc | Approx. -60 | ||
AUXILIARY CONNECTIONS | ||||
Interlock | Connector | 2 x BNC | For remote power inhibition (short is RF off) | |
Service | Connector | DB9 F | Factory reserved for firmware program | |
I²Cbus | Connector | DB9 F | ||
Telemetry interface | Connector | DB25 F | ||
FUSES | ||||
On mains | 1 External fuse F 16 – 5 x 20 mm | |||
On services | X | |||
On PA Supply | X | |||
On aux VDE Socket | X |